Request a Quote
Updated Date: 6th, Mar 2024

Key Factors to Consider When Selecting MCCBs

Key Factors to Consider When Selecting MCCBs

When designing and installing an electrical system, one of the most critical components is the circuit protection device. The molded case circuit breaker (MCCB) reigns supreme for providing optimized overcurrent protection. But with so many options on the market, how do you choose the right MCCB for your application? 

Several key factors must be evaluated to select the optimal product, such as:

Type and Rating

At the foundation, you’ll need to select the proper overall amp rating plus specific trip type matched to your loads and fault conditions. MCCBs come with varying trip types – B, C, D, K, and Z – that each feature unique time-current curve signatures. Choosing correctly protects equipment without nuisance tripping.

1. Type B MCCBs

The Type B trip curve offers a moderate level of magnetic protection, tripping in the range of 3-5 times the breaker’s current rating. With relatively slow tripping times between 0.04 and 13 seconds, Type B models work well for circuits with mostly resistive loads like heating elements or incandescent lighting. 

The gradual trip response prevents nuisance tripping on motor startups or temporary overloads. Type B breakers provide a sturdy, general-purpose option suitable for basic branch circuit protection.

2. Type C MCCBs

For applications with small inductive loads like single phase motors or transformers, Type C MCCBs offer faster magnetic tripping. They trip between 5-10 times their amp rating in 0.1 to 0.4 seconds. 

Their fast response can prevent damage from prolonged overloads. But Type C units may nuisance trip on large motor inrush currents. They strike a balance between Type B and the more sensitive Type D. Type C breakers provide a step up in speed and performance compared to general duty Type B models.

3. Type D MCCBs

With high magnetic trip levels between 10-20 times the rated current, Type D MCCBs prioritize load availability for inductive loads. Their fast trip time of 0.04-3 seconds manages severe overloads while avoiding nuisance trips from momentary spikes. 

Type D models work well for circuits containing motors, transformers, ballasts, and other inductive equipment prone to inrush currents. They deliver robust protection for industrial applications while minimizing downtime.

4. Type K MCCBs

For mission critical inductive loads requiring high inrush allowance, Type K MCCBs sustain 10-12 times rated current for up to 5 seconds before tripping. 

Their high magnetic pickup prevents tripping on startups. And the several second delay rides through temporary spikes before opening if faults persist. Type K units are ideal for high motor loads with frequent starts like conveyors or pumps. They maximize uptime but still quickly clear true faults.

5. Type Z MCCBs

At the most sensitive end of the spectrum, Type Z MCCBs offer the fastest protection. They trip magnetically at just 15-20 times rated load in under 300ms. 

Type Z breakers safeguard sensitive electronics and mission critical equipment where even short overloads can cause damage. However, their hair-trigger response risks nuisance trips. Carefully assess the priority between uptime and damage prevention when specifying Type Z MCCBs. Their meticulous sensitivity demands prudent and selective application.

For any MCCB type, ensure the amperage rating matches your expected load current plus 25-30% spare capacity. The voltage should meet or exceed the system voltage. Standard ratings align with wire and distribution equipment sizing conventions. Going too big or too small can decrease reliability or cause nuisance tripping.

Electrical Coordination

The second key factor is properly coordinating the MCCB within your system’s sequence of protection. Responsible for “tier two” circuit protection behind main breakers, MCCBs must be selective and cascading.

1. Selective Coordination

During overloads, the breaker nearest a fault should isolate it while others further upstream remain closed to maintain power to unaffected circuits. This selective tripping requires proper ampere sizing between MCCBs. Generally, feeder breakers must be 125-300% larger than branch circuit units they supply.

2. Cascade Coordination

Under short circuit conditions, the sequence needs controlled cascading. The breaker closest to the fault immediately trips. If it fails, the next upstream device quickly trips, followed by successive breakers until isolation occurs. This prevents breaker “blind spots”. Cascading depends on the specific trip time-current curves of each MCCB model.

Analyze the System

Confirm coordination by analyzing the prospective short circuit currents and modeling trip time-current curves in software. Overtripping from too many large MCCBs or undercoordination from oversized upstream units are common mistakes. Take the time to thoroughly study and test your system’s selectivity.

Physical Design

The final key factor is selecting the right physical MCCB design for your installation and operation needs:

1. Fixed vs Withdrawable

Fixed breakers bolt directly into place and cannot be easily removed. Withdrawable units connect into a chassis via a plug-in mechanism, allowing quick removal and exchange. Withdrawable breakers facilitate maintenance and replacements. But fixed models take up less space.

2. 1, 2, 3, or 4 Pole

Breakers come in 1, 2, 3, or 4 poles for the number of conductors they switch. Single pole units work for 120 VAC branch circuits. Three-phase loads need 2 or 3 poles. High-capacity systems use 4 poles. Match the poles to the type of circuit or equipment being protected.

3. Current and Future Space

Size the MCCB enclosure and number of poles for future expansion. Layout designs with 25-30% spare capacity to accommodate growth. Provisions like additional switchgear spaces and distribution blocks aid upgrades. Plan ahead!

4. Connections and Terminations

Choose between bolt-on, plug-in, and multiple rear connection options. Lugs must properly fit wire gauges. Ensure adequate wire bending space. Front connections simplify installation and inspection. Rear types save space but limit access.

5. Added Features

Modern MCCBs provide accessories like auxiliary switches, shunt trips, alarm switches, and motor operators. Determine which advanced features your application requires. But avoid over-specification that adds unnecessary cost and complexity.

MCCB Current Rating

This is a fundamental parameter to consider. It represents the maximum continuous current that the MCCB can handle. Even though the maximum current is reached, MCCB may still operate under normal conditions. 

MCCB Sizing Criteria

MCCBs are made in different sizes. They also come with different mounting options. Ensure that your desired MCCB fits within the physical constraints of your panel or enclosure.

You should also consider the mounting type of the MCCB. Your goal is to ensure compatibility with your existing setup. When installed properly, the MCCB can perform well and may last long.

MCCB Trip Settings and Adjustable Features

MCCBs typically include thermal and magnetic strip settings. The thermal trip setting protects against prolonged overloads. On the other hand, the magnetic trip setting protects against short circuits.

Look for models that come with adjustable trip settings. These allow for customization based on specific load characteristics. As you decide what MCCB to buy, consider whether the adjustable settings can be of benefit to you.

MCCB Breaking Capacity

When we say “breaking capacity” we are referring to the maximum fault current that the MCCB can safely interrupt without sustaining damage. This is also called the interrupting rating.

The rule of thumb is to select an MCCB whose breaking capacity exceeds the potential fault current in your system. This ensures that the device can handle severe fault conditions. Therefore, protecting your electrical equipment effectively.

MCCB Accessories

MCCB accessories can provide additional features and protection capabilities. Some key accessories are the following:

  • Auxiliary contacts
  • Shunt trips
  • Undervoltage releases

When considering MCCB accessories, evaluate your application’s specific requirements to determine which accessories are necessary. 

MCCB Poles

The number of poles in the MCCB must match your circuit configuration.

Number of PolesDescription
Single-poleSuitable for single-phase circuits.
Double-poleOften used for dual-phase or 240V circuits.
Triple-poleIdeal for three-phase circuits, providing protection for all three phases.
Four-PoleTypically used for three-phase circuits with a neutral, offering protection for all three phases and the neutral.

Choosing the right number of poles ensures that all parts of your circuit are adequately protected.

MCCB Pricing

MCCB pricing can vary widely based on several factors. Current rating, number of poles, breaking capacity, and additional features, all of these affect the price tag of MCCBs. Establishing a clear budget helps narrow down options. It also helps you to select an MCCB that meets your needs without exceeding financial limits. 

iALLWay: Makers of Reliable MCCBs

When it comes to selecting the right MCCB, having a reliable partner can make all the difference. iALLWay offers a comprehensive range of MCCBs tailored to meet various needs and applications. With a commitment to quality and customer satisfaction, this brand provides expert guidance and support to help you choose the ideal MCCB for your specific requirements.

Conclusion

Specifying the optimal MCCB is vital for power systems safety and reliability. By considering the type and ratings, coordination strategy, and physical construction, facilities can install robust overcurrent protection. 

Work closely with an expert like iALLway Electrical when selecting your MCCBs. Our licensed team provides tailored product selection and system analysis to protect your investment. With the right circuit protection partnership in place, you can power forward with confidence.

Article Sources
The iALLway exclusively utilizes high-quality sources, such as peer-reviewed studies, to substantiate the facts in our articles. Our dedication to accuracy and reliability guarantees that readers obtain well-researched and trustworthy information.
SHARE:
COMMENTS
rBjYocaISgQRWwf

ZiLPEFoYlbIG

To mt tài khon min phí

I don't think the title of your article matches the content lol. Just kidding, mainly because I had some doubts after reading the article.

LEAVE A COMMENT
RELATED POSTS
Request a quote
Attachment
×